  1. DOCUMENT:Q108412  15-DEC-1993  [W_NT]
  2. TITLE   :Exabyte 8200-EXB Streamer Time-Outs During Backup
  3. PRODUCT :Windows NT
  4. PROD/VER:3.10
  5. OPER/SYS:WINDOWS
  6. KEYWORDS:
  7.  
  8. --------------------------------------------------------------------------
  9. The information in this article applies to:
  10.  
  11.  - Microsoft Windows NT operating system version 3.1
  12. --------------------------------------------------------------------------
  13.  
  14. SYMPTOMS
  15. ========
  16.  
  17. When you are using the Exabyte 8200-EXB (SCSI-1 device) and backing up
  18. files with NTBACKUP, NTBACKUP stops after processing less than 1.5 megabyte
  19. (MB) of data. NTBACKUP displays the following error message:
  20.  
  21.    Fatal error 1.
  22.  
  23. The Event log contains the following message from the Service Control
  24. Manager:
  25.  
  26.    \Device\ScsiPort0 timed out.
  27.  
  28. RESOLUTION
  29. ==========
  30.  
  31. The Exabyte 8200-EXB can be configured for SCSI disconnects on even or odd
  32. byte boundaries. In order to operate properly with NTBACKUP, the streamer
  33. should be configured to disconnect on even boundary.
  34.  
  35. Configuration of the streamer is controlled by 8 dip-switches. Switch 3
  36. determines the SCSI disconnects. In order for NTBACKUP to operate
  37. correctly, switch 3 should be set On (Even boundary).
  38.  
  39. Detailed explanation of the dip-switches:
  40.  
  41. SW  Default value (Off)            Optional Value (On)
  42. ---------------------------------------------------------------------
  43. 1   Run Memory Test on             Bypass Memory Test on
  44.     Power-On Reset (65 sec)        Power-On-Reset (8 sec)
  45. 2   SCSI Parity Checking disabled  SCSI Parity Checking enabled
  46. 3   Odd or Even Byte disconnect    Even Byte disconnect
  47. 4   Report Busy Status             Non Busy Enabled
  48. 5   Fixed Block Mode on Power Up   Variable Block Mode on Power up
  49. 6   Normal Data Operation          No Disconnect During Data Transfer
  50. 7   Reserved                       Reserved
  51. 8   P6 Cartridge Type (106 meters) PI Cartridge Type (112 meters)
  52.  
  53. NOTE: Incorrect settings of any of these switches may cause problems with
  54. your configuration. Please consult your Exabyte documentation for more
  55. details on how to configure the streamer.
  56.  
  57. The Exabyte product included here is manufactured by a vendor independent
  58. of Microsoft; we make no warranty, implied or otherwise, regarding this
  59. product's performance or reliability.
  60.  
  61. Additional reference words: 3.10 Exabyte SCSI timeout third-party 3rdparty
  62. 3rd third party
  63. KBCategory:
  64. KBSubCategory: hrdwr
  65.  
  66. =============================================================================
  67.  
  68. THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS
  69. PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND.  MICROSOFT DISCLAIMS
  70. ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES
  71. OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  IN NO
  72. EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR
  73. ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL,
  74. CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF
  75. MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE
  76. POSSIBILITY OF SUCH DAMAGES.  SOME STATES DO NOT ALLOW THE EXCLUSION
  77. OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES
  78. SO THE FOREGOING LIMITATION MAY NOT APPLY.
  79.  
  80. Copyright Microsoft Corporation 1993.